HEAL DSpace

Temperature dependent dielectric spectroscopy in frequency domain of high-voltage transformer oils compared to physicochemical results

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Paraskevas, CD en
dc.contributor.author Vassiliou, P en
dc.contributor.author Dervos, CT en
dc.date.accessioned 2014-03-01T02:43:34Z
dc.date.available 2014-03-01T02:43:34Z
dc.date.issued 2005 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/31481
dc.subject Complex Permittivity en
dc.subject Dielectric Spectroscopy en
dc.subject Frequency Domain en
dc.subject High Voltage en
dc.subject Measurement Technique en
dc.subject Power Transformer en
dc.subject Temperature Dependence en
dc.subject thermally stimulated current en
dc.subject.other Data acquisition en
dc.subject.other Dielectric materials en
dc.subject.other Electric equipment en
dc.subject.other Frequency domain analysis en
dc.subject.other Thermal effects en
dc.subject.other Dielectric spectroscopy en
dc.subject.other Insulating transformer oils en
dc.subject.other Insulating oil en
dc.title Temperature dependent dielectric spectroscopy in frequency domain of high-voltage transformer oils compared to physicochemical results en
heal.type conferenceItem en
heal.identifier.primary 10.1109/ICDL.2005.1490081 en
heal.identifier.secondary http://dx.doi.org/10.1109/ICDL.2005.1490081 en
heal.publicationDate 2005 en
heal.abstract The temperature dependent dielectric spectroscopy in frequency domain, is compared to physicochemical and electrical tests that are periodically applied on highly insulating transformer oils. Complex permittivity and tanδ data are obtained as a function of frequency and operation temperatures, to demonstrate the polarization phenomena and the induced loss intensification by the thermally stimulated currents. The acquired dielectric data of oil samples collected from 201 operating HV power transformers, were correlated to their corresponding physicochemical ones in order to demonstrate the future potential employment of the proposed measuring technique in the field of high voltage engineering towards reliability monitoring of oil filled electrical equipment (OFEE). © 2005 IEEE. en
heal.journalName 2005 IEEE International Conference on Dielectric Liquids, ICDL 2005 en
dc.identifier.doi 10.1109/ICDL.2005.1490081 en
dc.identifier.spage 281 en
dc.identifier.epage 284 en