HEAL DSpace

Measurement of the magnetic field radiating by electrostatic discharge generators along various directions

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Fotis, GP en
dc.contributor.author Rapanakis, AG en
dc.contributor.author Gonos, IF en
dc.contributor.author Stathopulos, IA en
dc.date.accessioned 2014-03-01T02:44:05Z
dc.date.available 2014-03-01T02:44:05Z
dc.date.issued 2006 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/31671
dc.subject Electrostatic Discharge en
dc.subject Experimental Data en
dc.subject Magnetic Field en
dc.subject Near Field en
dc.subject.other Anechoic chambers en
dc.subject.other Electric discharges en
dc.subject.other Electrostatic generators en
dc.subject.other Magnetic field effects en
dc.subject.other Magnetic field measurement en
dc.subject.other Transients en
dc.subject.other Discharge point en
dc.subject.other Electrostatic Discharge (ESD) en
dc.subject.other Near field measurements en
dc.subject.other Pellegrini target en
dc.subject.other Electromagnetic waves en
dc.title Measurement of the magnetic field radiating by electrostatic discharge generators along various directions en
heal.type conferenceItem en
heal.identifier.primary 10.1109/CEFC-06.2006.1633148 en
heal.identifier.secondary 1633148 en
heal.identifier.secondary http://dx.doi.org/10.1109/CEFC-06.2006.1633148 en
heal.publicationDate 2006 en
heal.abstract The aim of this paper is to investigate the transient magnetic field radiating by Electrostatic Discharge (ESD) generators. Near field measurements have been conducted, a few centimeters far away from the discharge point (Pellegrini target). The Pellegrini target is mounted on the centre of a grounded metal plane, inside an anechoic chamber. The measurements were carried out to three different directions in relation to the discharge point. The experimental data show that each ESD generator produces a different transient magnetic field. Furthermore, additional differences referring to the produced magnetic field produced by each generator are noted, depending on the direction that the measurement is conducted. Finally, comparisons are stated concerning the magnetic field produced by each generator as well as useful conclusions for the decrease of the magnetic field. © 2006 IEEE. en
heal.journalName 12th Biennial IEEE Conference on Electromagnetic Field Computation, CEFC 2006 en
dc.identifier.doi 10.1109/CEFC-06.2006.1633148 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής