Determining appropriate magnetic core properties for a new type of flux-gate like sensor

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Petridis, C en
dc.contributor.author Petrou, I en
dc.contributor.author Dimitropoulos, P en
dc.contributor.author Hristoforou, E en
dc.date.accessioned 2014-03-01T02:44:35Z
dc.date.available 2014-03-01T02:44:35Z
dc.date.issued 2007 en
dc.identifier.issn 1546-198X en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/31880
dc.subject Demagnetization en
dc.subject Fluxgates en
dc.subject Hall sensors en
dc.subject Magnetization en
dc.subject.classification Chemistry, Analytical en
dc.subject.classification Electrochemistry en
dc.subject.classification Instruments & Instrumentation en
dc.subject.classification Physics, Applied en
dc.subject.other Amorphous materials en
dc.subject.other Demagnetization en
dc.subject.other Electromagnetic induction en
dc.subject.other Ferromagnetic materials en
dc.subject.other Magnetic cores en
dc.subject.other Magnetic properties en
dc.subject.other Magnetic variables measurement en
dc.subject.other Flux-gate like sensor en
dc.subject.other Fluxgates en
dc.subject.other Hall sensors en
dc.subject.other Nanosensors en
dc.title Determining appropriate magnetic core properties for a new type of flux-gate like sensor en
heal.type conferenceItem en
heal.identifier.primary 10.1166/sl.2007.072 en
heal.identifier.secondary http://dx.doi.org/10.1166/sl.2007.072 en
heal.language English en
heal.publicationDate 2007 en
heal.abstract In this paper a technique is presented concerning the characterization of magnetic properties of the sensing core of a new type of fluxgate sensor. The technique is based on the measurement of the magnetic induction of the ferromagnetic sensing core, going out of the material itself. Experiments using Vitrovac® Fe-Co rich rapidly quenched amorphous ribbons, Yttrium Iron Garnet (YIG) films and Ni80Fe20 films are presented illustrating that Vitrovac® and YIG films present the most sensitive response. The technique can also be used for other magnetic induction measurements for samples with thickness comparable to the Hall device active surface. Copyright © 2007 American Scientific Publishers. All rights reserved. en
heal.publisher AMER SCIENTIFIC PUBLISHERS en
heal.journalName Sensor Letters en
dc.identifier.doi 10.1166/sl.2007.072 en
dc.identifier.isi ISI:000245571600027 en
dc.identifier.volume 5 en
dc.identifier.issue 1 en
dc.identifier.spage 98 en
dc.identifier.epage 101 en