HEAL DSpace

Magnetostrictive delay lines for non-destructive testing

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Hristoforou, E en
dc.contributor.author Kosmas, K en
dc.date.accessioned 2014-03-01T02:44:49Z
dc.date.available 2014-03-01T02:44:49Z
dc.date.issued 2007 en
dc.identifier.issn 1383-5416 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/31956
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-34249694712&partnerID=40&md5=4feefd584d8690031ae4882d01993a78 en
dc.subject Magnetic non-destructive testing en
dc.subject Magnetostrictive delay lines en
dc.subject.classification Engineering, Electrical & Electronic en
dc.subject.classification Mechanics en
dc.subject.classification Physics, Applied en
dc.subject.other Acoustic wave velocity en
dc.subject.other Crack initiation en
dc.subject.other Eddy currents en
dc.subject.other Electric delay lines en
dc.subject.other Magnetic permeability en
dc.subject.other Nondestructive examination en
dc.subject.other Magnetoelastic performance en
dc.subject.other Magnetostrictive delay lines en
dc.subject.other Magnetostrictive ribbons en
dc.subject.other Magnetostrictive devices en
dc.title Magnetostrictive delay lines for non-destructive testing en
heal.type conferenceItem en
heal.language English en
heal.publicationDate 2007 en
heal.abstract In this paper, we summarize the magnetic and electromagnetic non-destructive testing techniques and devices based on the magnetostrictive delay line principle. Three main techniques are presented. The first is based on surface crack and defect detection on ferromagnetic surfaces by measuring the corresponding magnetic anomaly distribution. The second is the measurement of eddy currents generated around the cracks and defects on a magnetic or non-magnetic metallic surface. The third technique is measuring the surface magnetic permeability of ferromagnetic substances. Finally, the methods of measuring the properties of magnetostrictive ribbons and cylinders used as MDLs, such as magnetoelastic performance and longitudinal sound velocity as well as their uniformity measurements are also discussed. © 2007 - IOS Press and the authors. All rights reserved. en
heal.publisher IOS PRESS en
heal.journalName International Journal of Applied Electromagnetics and Mechanics en
dc.identifier.isi ISI:000248151100047 en
dc.identifier.volume 25 en
dc.identifier.issue 1-4 en
dc.identifier.spage 287 en
dc.identifier.epage 296 en