dc.contributor.author |
Kosmas, K |
en |
dc.contributor.author |
Hristoforou, E |
en |
dc.date.accessioned |
2014-03-01T02:44:58Z |
|
dc.date.available |
2014-03-01T02:44:58Z |
|
dc.date.issued |
2007 |
en |
dc.identifier.issn |
1383-5416 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/32063 |
|
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-34249714265&partnerID=40&md5=c515ecc6bee76c9944096019077d8081 |
en |
dc.subject |
Eddy currents |
en |
dc.subject |
Magnetic anomaly detection |
en |
dc.subject |
Magnetic non-destructive testing |
en |
dc.subject.classification |
Engineering, Electrical & Electronic |
en |
dc.subject.classification |
Mechanics |
en |
dc.subject.classification |
Physics, Applied |
en |
dc.subject.other |
Ferromagnetic materials |
en |
dc.subject.other |
Surface analysis |
en |
dc.subject.other |
Surface defects |
en |
dc.subject.other |
Ultrasonic testing |
en |
dc.subject.other |
Magnetic anomaly detection |
en |
dc.subject.other |
Magnetic nondestructive testing |
en |
dc.subject.other |
Parametric control |
en |
dc.subject.other |
Eddy current testing |
en |
dc.title |
The effect of magnetic anomaly detection technique in eddy current non-destructive testing |
en |
heal.type |
conferenceItem |
en |
heal.language |
English |
en |
heal.publicationDate |
2007 |
en |
heal.abstract |
In this paper, we demonstrate a first approach of a non destructive testing method that is being oriented in detecting mainly near subsurface defects in ferromagnetic materials. This new technique is related to the parametric control and combination of the classic magnetic anomaly detection and the eddy current techniques that can be potentially used in common geometries giving the possibility not only to reveal the presence of defects, but also lead to their reconstruction when being parallel or perpendicular to the under inspection surface. This method is limited in depths of few mm due to the barrier of the penetration of eddy currents but its contribution in non destructive testing is coplementary to that of ultrasonic testing. © 2007 - IOS Press and the authors. All rights reserved. |
en |
heal.publisher |
IOS PRESS |
en |
heal.journalName |
International Journal of Applied Electromagnetics and Mechanics |
en |
dc.identifier.isi |
ISI:000248151100051 |
en |
dc.identifier.volume |
25 |
en |
dc.identifier.issue |
1-4 |
en |
dc.identifier.spage |
319 |
en |
dc.identifier.epage |
324 |
en |