dc.contributor.author |
Prousalidis, J |
en |
dc.contributor.author |
Styvaktakis, E |
en |
dc.contributor.author |
Sofras, E |
en |
dc.contributor.author |
Hatzilau, IK |
en |
dc.contributor.author |
Muthumuni, D |
en |
dc.date.accessioned |
2014-03-01T02:45:00Z |
|
dc.date.available |
2014-03-01T02:45:00Z |
|
dc.date.issued |
2007 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/32089 |
|
dc.subject |
Power quality |
en |
dc.subject |
Ship power systems |
en |
dc.subject |
Voltage dips(sags) |
en |
dc.subject.other |
Electric transformers |
en |
dc.subject.other |
Power quality |
en |
dc.subject.other |
Ships |
en |
dc.subject.other |
Ship power systems |
en |
dc.subject.other |
Voltage dips(sags) |
en |
dc.subject.other |
Electric potential |
en |
dc.title |
Voltage dips in ship systems |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1109/ESTS.2007.372103 |
en |
heal.identifier.secondary |
4233839 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/ESTS.2007.372103 |
en |
heal.publicationDate |
2007 |
en |
heal.abstract |
In this paper, voltage dips (an important aspect of power quality) are presented in the context of ship power systems. Voltage dips are analyzed with respect to their origin (fault, motor starting, transformer saturation) considering the characteristics of the on-board installations. Emphasis is given to voltage dips and power quality issues of the All Electric Ship. Related issues are presented and discussed. © 2007 IEEE. |
en |
heal.journalName |
IEEE Electric Ship Technologies Symposium, ESTS 2007 |
en |