HEAL DSpace

Iron losses estimation using numerical methods in combination with experimental data

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Rovolis, PG en
dc.contributor.author Kladas, AG en
dc.date.accessioned 2014-03-01T02:45:31Z
dc.date.available 2014-03-01T02:45:31Z
dc.date.issued 2008 en
dc.identifier.issn 02759306 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/32293
dc.subject Electrical Machine en
dc.subject Experimental Data en
dc.subject Hysteresis Loop en
dc.subject Iron en
dc.subject Numerical Method en
dc.subject.other Hysteresis en
dc.subject.other Hysteresis loops en
dc.subject.other Iron en
dc.subject.other Laminating en
dc.subject.other Machine design en
dc.subject.other Magnetic materials en
dc.subject.other Magnetism en
dc.subject.other Numerical methods en
dc.subject.other Optical losses en
dc.subject.other Power electronics en
dc.subject.other Distorted grid voltage en
dc.subject.other Dynamic effects en
dc.subject.other Electrical machines en
dc.subject.other Experimental data en
dc.subject.other Harmonic frequencies en
dc.subject.other Iron cores en
dc.subject.other Iron losses en
dc.subject.other Jiles-Atherton model en
dc.subject.other Sinusoidal excitations en
dc.subject.other Variable frequencies en
dc.subject.other Variable speed en
dc.subject.other Iron analysis en
dc.title Iron losses estimation using numerical methods in combination with experimental data en
heal.type conferenceItem en
heal.identifier.primary 10.1109/PESC.2008.4592236 en
heal.identifier.secondary http://dx.doi.org/10.1109/PESC.2008.4592236 en
heal.identifier.secondary 4592236 en
heal.publicationDate 2008 en
heal.abstract Iron loss analysis is important for transformer and electrical machine design. Especially, operation under distorted grid voltage waveforms and variable speed motors supplied by inverters present increased iron losses due to harmonic frequencies. The paper presents a methodology for determination of variable frequency iron losses in laminated iron cores under sinusoidal excitation. The method is based on a convenient modification of Jiles-Atherton model enabling to account for dynamic effects. The model tuning is performed by using measured hysteresis loops in iron laminations for sinusoidal excitation of various frequencies in Epstein device. ©2008 IEEE. en
heal.journalName PESC Record - IEEE Annual Power Electronics Specialists Conference en
dc.identifier.doi 10.1109/PESC.2008.4592236 en
dc.identifier.spage 1995 en
dc.identifier.epage 1998 en