HEAL DSpace

Simulating dynamic B-mode ultrasound image data of the common carotid artery

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Stoitsis, J en
dc.contributor.author Golemati, S en
dc.contributor.author Koropouli, V en
dc.contributor.author Nikita, KS en
dc.date.accessioned 2014-03-01T02:45:47Z
dc.date.available 2014-03-01T02:45:47Z
dc.date.issued 2008 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/32391
dc.subject Carotid artery en
dc.subject FIELD II en
dc.subject Motion en
dc.subject Simulation en
dc.subject Ultrasound en
dc.subject.other Acoustic waves en
dc.subject.other Conformal mapping en
dc.subject.other Deformation en
dc.subject.other Digital image storage en
dc.subject.other Functions en
dc.subject.other Imaging systems en
dc.subject.other Mathematical models en
dc.subject.other Optoelectronic devices en
dc.subject.other Technical presentations en
dc.subject.other Ultrasonic transmission en
dc.subject.other Ultrasonics en
dc.subject.other Carotid artery en
dc.subject.other FIELD II en
dc.subject.other Motion en
dc.subject.other Simulation en
dc.subject.other Ultrasound en
dc.subject.other Ultrasonic imaging en
dc.title Simulating dynamic B-mode ultrasound image data of the common carotid artery en
heal.type conferenceItem en
heal.identifier.primary 10.1109/IST.2008.4659958 en
heal.identifier.secondary http://dx.doi.org/10.1109/IST.2008.4659958 en
heal.identifier.secondary 4659958 en
heal.publicationDate 2008 en
heal.abstract Motion of the carotid artery wall from sequences of ultrasound images has been promising in providing useful indices characterizing elasticity of healthy and diseased arterial wall. The validation of motion analysis algorithms remains, however, a challenging task mainly because the actual tissue motion field is not readily available. In this paper, a methodology is suggested for the generation of simulated dynamic B-mode ultrasound image data of the common carotid artery. The approach consists of three main stages: (a) the generation of a scattering map using a real ultrasound image as a template, (b) the assumption of a mathematical model of arterial wall deformation in the radial and axial directions and (c) the generation of simulated sequential data by displacing the scattering map according to the deformation model. The procedure is based on the use of FIELD II, an ultrasound simulation package incorporating realistic transducer features. A total of 29 frames with a temporal separation of 0.04s were generated covering a cardiac cycle of approximately 1.16s duration. The simulation procedure is computationally expensive, but the resulting dynamic image data can be used efficiently in tasks involving evaluation of motion analysis algorithms. ©2008 IEEE. en
heal.journalName IST 2008 - IEEE Workshop on Imaging Systems and Techniques Proceedings en
dc.identifier.doi 10.1109/IST.2008.4659958 en
dc.identifier.spage 144 en
dc.identifier.epage 148 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής