HEAL DSpace

Local voltage instability monitoring and protection in the presence of self-restoring loads and two-level LTCs

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Lambrou, C en
dc.contributor.author Mandoulidis, P en
dc.contributor.author Vournas, C en
dc.date.accessioned 2014-03-01T02:47:24Z
dc.date.available 2014-03-01T02:47:24Z
dc.date.issued 2011 en
dc.identifier.issn 19449925 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/33122
dc.subject Load Tap Changers en
dc.subject protection against voltage collapse en
dc.subject restorative load en
dc.subject voltage instability monitoring en
dc.subject Voltage stability en
dc.subject.other Bulk power en
dc.subject.other Corrective measures en
dc.subject.other Distribution voltages en
dc.subject.other Load tap changer en
dc.subject.other LTC transformers en
dc.subject.other protection against voltage collapse en
dc.subject.other Protection systems en
dc.subject.other restorative load en
dc.subject.other Stable operation en
dc.subject.other Test systems en
dc.subject.other Voltage instability en
dc.subject.other Electric power transmission en
dc.subject.other Electric utilities en
dc.subject.other Transformer protection en
dc.subject.other Voltage control en
dc.subject.other Stability en
dc.title Local voltage instability monitoring and protection in the presence of self-restoring loads and two-level LTCs en
heal.type conferenceItem en
heal.identifier.primary 10.1109/PES.2011.6039524 en
heal.identifier.secondary http://dx.doi.org/10.1109/PES.2011.6039524 en
heal.identifier.secondary 6039524 en
heal.publicationDate 2011 en
heal.abstract In this paper we give an overview of a local voltage instability monitoring and protection system integrated in the controller of each bulk power delivery LTC transformer. The proposed system identifies imminent voltage instability and subsequently applies corrective measures to restore stable operation by properly adjusting the distribution voltage setpoint of the LTC. The system is extended in this paper to include also the LTCs acting on EHV/HV autotransformers and is checked in the presence of self-restoring loads. Application on a small test system and a 52-bus test system shows the performance of the proposed system and the associated problems and solutions. © 2011 IEEE. en
heal.journalName IEEE Power and Energy Society General Meeting en
dc.identifier.doi 10.1109/PES.2011.6039524 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής