dc.contributor.author |
Bourkas, P |
en |
dc.contributor.author |
Karagiannopoulos, C |
en |
dc.contributor.author |
Dervos, C |
en |
dc.contributor.author |
Kagarakis, C |
en |
dc.date.accessioned |
2014-03-01T02:47:56Z |
|
dc.date.available |
2014-03-01T02:47:56Z |
|
dc.date.issued |
1991 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/33450 |
|
dc.subject |
Contact Resistance |
en |
dc.subject |
Copper |
en |
dc.subject |
Current Density |
en |
dc.subject |
Experimental Procedure |
en |
dc.subject |
Room Temperature |
en |
dc.title |
An experimental investigation of the metal contacts resistance at initial stages of operation |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1109/MELCON.1991.162120 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/MELCON.1991.162120 |
en |
heal.publicationDate |
1991 |
en |
heal.abstract |
An experimental procedure is described whose objective is the determination of the thermal coefficient, α, in relation to the crossing resistance for copper contacts which have undergone aging under conditions of real operation (200 h) during which surface degradation was generated in a natural manner. It is clear that at the first stages of reoperation (after a few hours of |
en |
heal.journalName |
MELECON - IEEE Mediterranean Electrotechnical Conference |
en |
dc.identifier.doi |
10.1109/MELCON.1991.162120 |
en |