HEAL DSpace

A new approach in the determination of patient's reference point in conformal external radiotherapy

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Antonios, K en
dc.contributor.author Maria, P en
dc.contributor.author Dimos, B en
dc.contributor.author Dimitrios, K en
dc.date.accessioned 2014-03-01T02:49:59Z
dc.date.available 2014-03-01T02:49:59Z
dc.date.issued 2005 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/34844
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-27844497697&partnerID=40&md5=38c71eb938e3b97010f410397a043447 en
dc.subject Image processing en
dc.subject Patient's set-up en
dc.subject Radiotherapy en
dc.subject.other Computer simulation en
dc.subject.other Computer software en
dc.subject.other Image processing en
dc.subject.other Irradiation en
dc.subject.other Medical imaging en
dc.subject.other Radiotherapy en
dc.subject.other Patient's set-up en
dc.subject.other Reference point en
dc.subject.other Treatment phase en
dc.subject.other Patient treatment en
dc.title A new approach in the determination of patient's reference point in conformal external radiotherapy en
heal.type conferenceItem en
heal.publicationDate 2005 en
heal.abstract Our study involves mainly patient's immobilization and imaging in conformal radiotherapy process. The goal is the accurate automatic determination of the patient's reference point in regard to table coordinates, which is very important for the successful execution of the whole treatment, as patient's set up must be literally maintained between imaging and treatment phase. The significance of the determination of the reference point, emerge in the treatment phase for the accurate transfer of the planned irradiation technique to the patient. The determination of RP to table coordinates is based mainly on detection of markers on patient's skin and in table in a DICOM image, generated during the imaging process. The results are compared with the same results acquired manually by a tape measure and by the use of commercial software for 3D simulation of external beam radiation therapy. en
heal.journalName Proceedings of the 3rd IASTED International Conference on Biomedical Engineering 2005 en
dc.identifier.spage 54 en
dc.identifier.epage 58 en