HEAL DSpace

A binocular machine vision system for non-melanoma skin cancer 3D reconstruction

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Gorpas, DS en
dc.contributor.author Politopoulos, K en
dc.contributor.author Alexandratou, E en
dc.contributor.author Yova, D en
dc.date.accessioned 2014-03-01T02:50:17Z
dc.date.available 2014-03-01T02:50:17Z
dc.date.issued 2006 en
dc.identifier.issn 0277786X en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/35029
dc.subject 3D Skin Tumor Imaging en
dc.subject Calibration en
dc.subject Conjugate Points en
dc.subject PDT Assessment en
dc.subject Structured Light en
dc.subject.other Binoculars en
dc.subject.other Calibration en
dc.subject.other Image reconstruction en
dc.subject.other Skin en
dc.subject.other Tumors en
dc.subject.other Volumetric analysis en
dc.subject.other 3D Skin Tumor Imaging en
dc.subject.other Conjugate Points en
dc.subject.other PDT Assessment en
dc.subject.other Structured Light en
dc.subject.other Computer vision en
dc.title A binocular machine vision system for non-melanoma skin cancer 3D reconstruction en
heal.type conferenceItem en
heal.identifier.primary 10.1117/12.643780 en
heal.identifier.secondary http://dx.doi.org/10.1117/12.643780 en
heal.identifier.secondary 60810D en
heal.publicationDate 2006 en
heal.abstract Computer vision advancements have not till now achieved the accurate 3D reconstruction of objects smaller than 1cm diameter. Although this problem is of great importance in dermatology for Non Melanoma Skin Cancer diagnosis and therapy, has not yet been solved. This paper describes the development of a novel volumetric method for NMSC animal model tumors, using a binocular vision system. Monitoring NMSC tumors volume changes during PDT will grant important information for the assessment of the therapeutic progress and the efficiency of the applied drug. The vision system was designed taking into account the targets size and the flexibility. By using high resolution cameras with telecentric lenses most distortion factors were reduced significantly. Furthermore, z-axis movement was possible without requiring calibration, in contrary to wide angle lenses. The calibration was achieved by means of adapted photogrammetric technique. The required time for calibrating both cameras was less than a minute. For accuracy expansion, a structured light projector was used. The captured stereo-pair images were processed with modified morphological filters to improve background contrast and minimize noise. The determination of conjugate points was achieved via maximum correlation values and region properties, thus decreasing significantly the computational cost. The 3D reconstruction algorithm has been assessed with objects of known volumes and applied to animal model tumors with less than 0.6cm diameter. The achieved precision was at very high levels providing a standard deviation of 0.0313mm. The robustness of our system is based on the overall approach and on the size of the targets. en
heal.journalName Proceedings of SPIE - The International Society for Optical Engineering en
dc.identifier.doi 10.1117/12.643780 en
dc.identifier.volume 6081 en


Αρχεία σε αυτό το τεκμήριο