dc.contributor.author |
Spyratou, E |
en |
dc.contributor.author |
Voloudakis, GE |
en |
dc.contributor.author |
Moutsouris, K |
en |
dc.contributor.author |
Asproudis, I |
en |
dc.contributor.author |
Baltatzis, S |
en |
dc.contributor.author |
Makropoulou, M |
en |
dc.contributor.author |
Bacharis, C |
en |
dc.contributor.author |
Serafetinides, AA |
en |
dc.date.accessioned |
2014-03-01T02:51:35Z |
|
dc.date.available |
2014-03-01T02:51:35Z |
|
dc.date.issued |
2008 |
en |
dc.identifier.issn |
0277786X |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/35571 |
|
dc.subject |
Cornea ablation |
en |
dc.subject |
Er:YAG laser |
en |
dc.subject |
Histology analysis |
en |
dc.subject |
Mid-infrared laser |
en |
dc.subject |
Nd:YAG laser |
en |
dc.subject |
SEM |
en |
dc.subject |
UV solid state laser |
en |
dc.subject.other |
Biological radiation effects |
en |
dc.subject.other |
Electron optics |
en |
dc.subject.other |
Erbium |
en |
dc.subject.other |
Histology |
en |
dc.subject.other |
Infrared devices |
en |
dc.subject.other |
Infrared spectroscopy |
en |
dc.subject.other |
Laser ablation |
en |
dc.subject.other |
Laser pulses |
en |
dc.subject.other |
Lasers |
en |
dc.subject.other |
Neodymium |
en |
dc.subject.other |
Optical parametric oscillators |
en |
dc.subject.other |
Pulsed laser applications |
en |
dc.subject.other |
Quantum electronics |
en |
dc.subject.other |
Scanning electron microscopy |
en |
dc.subject.other |
Solid state lasers |
en |
dc.subject.other |
Surface roughness |
en |
dc.subject.other |
Cornea ablation |
en |
dc.subject.other |
Er:YAG laser |
en |
dc.subject.other |
Mid-infrared laser |
en |
dc.subject.other |
Nd:YAG laser |
en |
dc.subject.other |
SEM |
en |
dc.subject.other |
UV solid state laser |
en |
dc.subject.other |
Neodymium lasers |
en |
dc.title |
Corneal morphology after ex-vivo UV and mid-infrared laser ablation |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1117/12.822524 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1117/12.822524 |
en |
heal.identifier.secondary |
70271B |
en |
heal.publicationDate |
2008 |
en |
heal.abstract |
In this work, ablation experiments of ex vivo porcine cornea tissue were conducted with two solid state lasers (an Er:YAG laser and the 4th harmonic of an Nd:YAG laser, both in the ns pulse width range) emitting in mid infrared and ultraviolet part of the spectrum respectively, at moderate laser fluences. The cornea epithelium of each porcine eye was manually removed before the ablation. Histology analysis of the specimens was performed, in order to examine the microscopic appearance of the ablated craters and the existence of any thermal or mechanical damage caused by the midinfrared and the UV laser irradiation. For a detailed and complete examination of the morphology of the laser ablated corneal tissue, the surface roughness was investigated by scanning electron microscopy. © 2008 SPIE. |
en |
heal.journalName |
Proceedings of SPIE - The International Society for Optical Engineering |
en |
dc.identifier.doi |
10.1117/12.822524 |
en |
dc.identifier.volume |
7027 |
en |