dc.contributor.author |
Kefalas, TD |
en |
dc.contributor.author |
Kladas, AG |
en |
dc.date.accessioned |
2014-03-01T02:52:41Z |
|
dc.date.available |
2014-03-01T02:52:41Z |
|
dc.date.issued |
2010 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/35995 |
|
dc.subject |
Computer aided analysis |
en |
dc.subject |
Finite element methods |
en |
dc.subject |
Industrial power system harmonics |
en |
dc.subject |
Magnetic cores |
en |
dc.subject |
Magnetic hysteresis |
en |
dc.subject |
Magnetic losses |
en |
dc.subject |
Nonlinear magnetics |
en |
dc.subject |
Numerical analysis |
en |
dc.subject |
Power transformers |
en |
dc.subject.other |
Design tool |
en |
dc.subject.other |
Distribution transformer |
en |
dc.subject.other |
Energy efficient |
en |
dc.subject.other |
European Union |
en |
dc.subject.other |
Experimental procedure |
en |
dc.subject.other |
Finite Element |
en |
dc.subject.other |
Finite element codes |
en |
dc.subject.other |
Grid voltage |
en |
dc.subject.other |
Harmonic loss |
en |
dc.subject.other |
Hysteresis phenomenon |
en |
dc.subject.other |
Industrial power system harmonics |
en |
dc.subject.other |
Magnetic loss |
en |
dc.subject.other |
Nonlinear magnetics |
en |
dc.subject.other |
Supply voltages |
en |
dc.subject.other |
Voltage harmonics |
en |
dc.subject.other |
Computer aided analysis |
en |
dc.subject.other |
Electric power distribution |
en |
dc.subject.other |
Energy conversion |
en |
dc.subject.other |
Finite element method |
en |
dc.subject.other |
Harmonic analysis |
en |
dc.subject.other |
Magnetic circuits |
en |
dc.subject.other |
Magnetic cores |
en |
dc.subject.other |
Magnetic devices |
en |
dc.subject.other |
Magnetic hysteresis |
en |
dc.subject.other |
Magnetism |
en |
dc.subject.other |
Numerical methods |
en |
dc.subject.other |
Transformer substations |
en |
dc.subject.other |
Power transformers |
en |
dc.title |
Grid voltage harmonics effect on distribution transformer operation |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1049/cp.2010.0894 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1049/cp.2010.0894 |
en |
heal.publicationDate |
2010 |
en |
heal.abstract |
Distribution transformer operation is sensitive to the distortion of the supply voltage waveform. According to Strategies for development and diffusion of Energy Efficient Distribution Transformers (SEEDT), reactive power and harmonic losses add a further 5 TWh/year to the losses of European Union (EU-27) distribution transformers. In the present paper a systematic experimental procedure is developed in order to evaluate the effect of voltage harmonics on distribution transformer operation. Also, a theoretical analysis based on the hysteresis design tool of Matlab and a finite element code integrating the hysteresis phenomena is carried out. |
en |
heal.journalName |
IET Conference Publications |
en |
dc.identifier.doi |
10.1049/cp.2010.0894 |
en |
dc.identifier.volume |
2010 |
en |
dc.identifier.issue |
572 CP |
en |