dc.contributor.author |
Manousakis, NM |
en |
dc.contributor.author |
Korres, GN |
en |
dc.date.accessioned |
2014-03-01T02:52:43Z |
|
dc.date.available |
2014-03-01T02:52:43Z |
|
dc.date.issued |
2010 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/36018 |
|
dc.subject |
Flow islands |
en |
dc.subject |
Gram matrix |
en |
dc.subject |
Observability restoration |
en |
dc.subject |
Phasor measurement units |
en |
dc.subject |
Triangular factors |
en |
dc.subject.other |
Boundary bus |
en |
dc.subject.other |
Branch currents |
en |
dc.subject.other |
Bus systems |
en |
dc.subject.other |
Bus voltage |
en |
dc.subject.other |
Conventional measurements |
en |
dc.subject.other |
Direct method |
en |
dc.subject.other |
Flow islands |
en |
dc.subject.other |
Gram matrices |
en |
dc.subject.other |
Gram matrix |
en |
dc.subject.other |
Injection measurement |
en |
dc.subject.other |
Jacobians |
en |
dc.subject.other |
Measurement system |
en |
dc.subject.other |
Observability analysis |
en |
dc.subject.other |
Phasor measurement unit |
en |
dc.subject.other |
Phasor measurement units |
en |
dc.subject.other |
Phasor measurements |
en |
dc.subject.other |
Power systems |
en |
dc.subject.other |
Reduced order |
en |
dc.subject.other |
Reduced size |
en |
dc.subject.other |
Triangular factorization |
en |
dc.subject.other |
Triangular factors |
en |
dc.subject.other |
Unobservable |
en |
dc.subject.other |
Direct injection |
en |
dc.subject.other |
Electric power system interconnection |
en |
dc.subject.other |
Energy conversion |
en |
dc.subject.other |
Jacobian matrices |
en |
dc.subject.other |
Numerical methods |
en |
dc.subject.other |
Observability |
en |
dc.subject.other |
Phase measurement |
en |
dc.subject.other |
Restoration |
en |
dc.subject.other |
Units of measurement |
en |
dc.subject.other |
Flow measurement |
en |
dc.title |
Observability analysis for power systems including conventional and phasor measurements |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1049/cp.2010.0892 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1049/cp.2010.0892 |
en |
heal.publicationDate |
2010 |
en |
heal.abstract |
This paper presents a numerical method for observability analysis of a measurement system including phasor measurement units (PMUs) as well as conventional measurements. Traditional power flow measurements and branch current phasor measurements are used to build topologically flow islands that, in turn, are used to construct a reduced network. Boundary injections at flow islands and bus voltage phasors are considered to form a reduced size Jacobian matrix. Observability checking is carried out analyzing the pivots encountered during the triangular factorization of a Gram matrix associated with this reduced order Jacobian. The additional measurements, that restore the global observability of an unobservable system, are provided by a direct method, using the triangular factors of a Gram matrix associated with a reduced Jacobian including existing and candidate traditional injection measurements as well as PMUs, at boundary buses of the flow islands. The IEEE 14-bus system demonstrates the features of the proposed method. |
en |
heal.journalName |
IET Conference Publications |
en |
dc.identifier.doi |
10.1049/cp.2010.0892 |
en |
dc.identifier.volume |
2010 |
en |
dc.identifier.issue |
572 CP |
en |