HEAL DSpace

Comparison of iron losses in multiple grain size iron laminations under sinusoidal and SPWM excitation

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Rovolis, P en
dc.contributor.author Kladas, A en
dc.contributor.author Tegopoulos, J en
dc.date.accessioned 2014-03-01T02:52:56Z
dc.date.available 2014-03-01T02:52:56Z
dc.date.issued 2011 en
dc.identifier.issn 02555476 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/36160
dc.subject Epstein device en
dc.subject Iron Losses en
dc.subject Laminated iron en
dc.subject SPWM supply en
dc.subject.other Data acquisition cards en
dc.subject.other Epstein device en
dc.subject.other Flux densities en
dc.subject.other Fundamental frequencies en
dc.subject.other Iron cores en
dc.subject.other Iron loss en
dc.subject.other Iron Losses en
dc.subject.other Laminated iron en
dc.subject.other Multiple grains en
dc.subject.other Sinusoidal excitations en
dc.subject.other Sinusoidal pulse en
dc.subject.other SPWM supply en
dc.subject.other Voltage excitations en
dc.subject.other Electromagnetism en
dc.subject.other Laminating en
dc.subject.other Magnetic materials en
dc.subject.other Superconductivity en
dc.subject.other Superconducting materials en
dc.title Comparison of iron losses in multiple grain size iron laminations under sinusoidal and SPWM excitation en
heal.type conferenceItem en
heal.identifier.primary 10.4028/www.scientific.net/MSF.670.74 en
heal.identifier.secondary http://dx.doi.org/10.4028/www.scientific.net/MSF.670.74 en
heal.publicationDate 2011 en
heal.abstract The paper presents a methodology for determination of harmonic iron losses in laminated iron cores under both sinusoidal and sinusoidal pulse width modulated voltage excitations (SPWM) excitation for various frequencies. The method is based on measurements performed by using a convenient Epstein device supplied by a sinusoidal and a SPWM source, which are stored and processed in a PC by using an appropriate data acquisition card. It is shown that the switching frequency does not considerably affect iron losses under SPWM supply and vary non-linearly with flux density with respect to the ones measured under sinusoidal excitation for the same fundamental frequency. en
heal.journalName Materials Science Forum en
dc.identifier.doi 10.4028/www.scientific.net/MSF.670.74 en
dc.identifier.volume 670 en
dc.identifier.spage 74 en
dc.identifier.epage 81 en