HEAL DSpace

Combined three-dimensional computer vision and epi-illumination fluorescence imaging system

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Gorpas, D en
dc.contributor.author Yova, D en
dc.contributor.author Politopoulos, K en
dc.date.accessioned 2014-03-01T02:53:35Z
dc.date.available 2014-03-01T02:53:35Z
dc.date.issued 2012 en
dc.identifier.issn 16057422 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/36427
dc.subject Binocular machine vision en
dc.subject Camera calibration en
dc.subject Epi-illumination system en
dc.subject Excitation source calibration en
dc.subject Fluorescence imaging en
dc.subject Telecentric lens en
dc.subject.other Binocular machine vision en
dc.subject.other Camera calibration en
dc.subject.other Epi-illumination en
dc.subject.other Excitation sources en
dc.subject.other Fluorescence imaging en
dc.subject.other Binoculars en
dc.subject.other Calibration en
dc.subject.other Computer vision en
dc.subject.other Fluorescence en
dc.subject.other Imaging systems en
dc.subject.other Inspection en
dc.subject.other Inverse problems en
dc.subject.other Mean square error en
dc.subject.other Medical imaging en
dc.subject.other Tissue en
dc.subject.other Three dimensional en
dc.title Combined three-dimensional computer vision and epi-illumination fluorescence imaging system en
heal.type conferenceItem en
heal.identifier.primary 10.1117/12.907786 en
heal.identifier.secondary 82160N en
heal.identifier.secondary http://dx.doi.org/10.1117/12.907786 en
heal.publicationDate 2012 en
heal.abstract Most of the reported fluorescence imaging methods and systems highlight the need for three-dimensional information of the inspected region surface geometry. The scope of this manuscript is to introduce an epi-illumination fluorescence imaging system, which has been enhanced with a binocular machine vision system for the translation of the inverse problem solution to the global coordinates system. The epi-illumination fluorescence imaging system is consisted of a structured scanning excitation source, which increases the spatial differentiation of the measured data, and a telecentric lens, which increases the angular differentiation. On the other hand, the binocular system is based on the projection of a structured light pattern on the inspected area, for the solution of the correspondence problem between the stereo pair. The functionality of the system has been evaluated on tissue phantoms and calibration objects. The reconstruction accuracy of the fluorophores distribution, as resulted from the root mean square error between the actual distribution and the outcome of the forward solver, was more than 80%. On the other hand, the surface three-dimensional reconstruction of the inspected region presented 0.067±0.004 mm accuracy, as resulted from the mean Euclidean distance between the three-dimensional position of the real world points and those reconstructed. © 2012 SPIE. en
heal.journalName Progress in Biomedical Optics and Imaging - Proceedings of SPIE en
dc.identifier.doi 10.1117/12.907786 en
dc.identifier.volume 8216 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)