HEAL DSpace

Design and simulation of a data transmission network for industrial control system subject to reliability improvement

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Mahmood, MK en
dc.contributor.author Al-Naima, FM en
dc.contributor.author Uzunoglu, NK en
dc.date.accessioned 2014-03-01T02:53:36Z
dc.date.available 2014-03-01T02:53:36Z
dc.date.issued 2012 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/36441
dc.subject DCS en
dc.subject Intranet en
dc.subject OPNET en
dc.subject Protocols en
dc.subject Reliability en
dc.subject.other Data communication networks en
dc.subject.other Database access en
dc.subject.other DCS en
dc.subject.other Design and simulation en
dc.subject.other File transfer protocols en
dc.subject.other High load en
dc.subject.other Industrial control systems en
dc.subject.other Network simulators en
dc.subject.other Oil refineries en
dc.subject.other OPNET en
dc.subject.other OPNET Modeler en
dc.subject.other Performance evaluation en
dc.subject.other Real-time data communication en
dc.subject.other Reliability improvement en
dc.subject.other Topological changes en
dc.subject.other Utilization factor en
dc.subject.other Voice over IP en
dc.subject.other Convolutional codes en
dc.subject.other Data communication systems en
dc.subject.other Distributed parameter control systems en
dc.subject.other Distributed parameter networks en
dc.subject.other Industrial plants en
dc.subject.other Internet telephony en
dc.subject.other Intranets en
dc.subject.other Network protocols en
dc.subject.other Reliability en
dc.subject.other Computer simulation en
dc.title Design and simulation of a data transmission network for industrial control system subject to reliability improvement en
heal.type conferenceItem en
heal.identifier.primary 10.1109/ICFCN.2012.6206867 en
heal.identifier.secondary http://dx.doi.org/10.1109/ICFCN.2012.6206867 en
heal.identifier.secondary 6206867 en
heal.publicationDate 2012 en
heal.abstract This paper presents the design and simulation of a reliable data communication network. Real time data communication network with high load File Transfer Protocol (FTP), database access, E-mail and Voice over IP (VoIP) with PCM quality application are simulated subject to reliability study. OPNET Modeler 14.5 is used as network simulator. Many models are considered in the simulation and tested against many cases (high load, utilization factor of links, network topological change). The simulation results are analyzed and discussed based on the case study of building an Intranet for the North Oil Refineries of Baiji (NORB) in Iraq. This paper deals with performance evaluation of industrial plant Intranet used to interconnect several Distributed Control Systems (DCS) and the evaluation of real-time parameters describing the behavior of the network. © 2012 IEEE. en
heal.journalName 2012 International Conference on Future Communication Networks, ICFCN 2012 en
dc.identifier.doi 10.1109/ICFCN.2012.6206867 en
dc.identifier.spage 23 en
dc.identifier.epage 28 en