dc.contributor.author |
Kefalas, TD |
en |
dc.contributor.author |
Kladas, AG |
en |
dc.date.accessioned |
2014-03-01T02:53:54Z |
|
dc.date.available |
2014-03-01T02:53:54Z |
|
dc.date.issued |
2012 |
en |
dc.identifier.issn |
00189464 |
en |
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/36485 |
|
dc.subject |
Magnetic cores |
en |
dc.subject |
magnetic field measurement |
en |
dc.subject |
magnetic losses |
en |
dc.subject |
power transformers |
en |
dc.subject.other |
Excitation currents |
en |
dc.subject.other |
Experimental evidence |
en |
dc.subject.other |
Flux densities |
en |
dc.subject.other |
Flux distributions |
en |
dc.subject.other |
Grain oriented electrical steel |
en |
dc.subject.other |
Grain-oriented steel |
en |
dc.subject.other |
Harmonics content |
en |
dc.subject.other |
High magnetization |
en |
dc.subject.other |
High permeability |
en |
dc.subject.other |
Low costs |
en |
dc.subject.other |
Low permeability |
en |
dc.subject.other |
Nonuniformity |
en |
dc.subject.other |
Three-phase transformers |
en |
dc.subject.other |
Transformer core |
en |
dc.subject.other |
Wave forms |
en |
dc.subject.other |
Wound core |
en |
dc.subject.other |
Magnetic cores |
en |
dc.subject.other |
Magnetic field measurement |
en |
dc.subject.other |
Magnetic leakage |
en |
dc.subject.other |
Power transformers |
en |
dc.subject.other |
Silicon steel |
en |
dc.subject.other |
Silicon |
en |
dc.title |
Mixed Si-Fe wound cores five legged transformer: Losses and flux distribution analysis |
en |
heal.type |
conferenceItem |
en |
heal.identifier.primary |
10.1109/TMAG.2011.2172929 |
en |
heal.identifier.secondary |
http://dx.doi.org/10.1109/TMAG.2011.2172929 |
en |
heal.identifier.secondary |
6172335 |
en |
heal.publicationDate |
2012 |
en |
heal.abstract |
This paper proposes a three-phase five legged wound transformer core constructed of two high permeability Si-Fe wound cores and two conventional Si-Fe wound cores. The two large internal wound cores are manufactured of high permeability, grain-oriented electrical steel. The two small outer wound cores are manufactured of conventional, grain-oriented electrical steel. The specific arrangement is based on experimental evidence concerning the peak flux density non-uniformity of the typical three-phase five legged wound transformer core, constructed of the high magnetization grain-oriented steel. Since the peak flux density of the two outer cores is lower than the two internal cores, low cost, low permeability, conventional grain-oriented electrical steel can be used for the outer cores. Losses, excitation currents, flux waveforms, and their harmonics contents are presented in this paper. A comparison of the mixed three-phase transformer core and the typical one is also carried out. © 2006 IEEE. |