HEAL DSpace

Mixed Si-Fe wound cores five legged transformer: Losses and flux distribution analysis

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kefalas, TD en
dc.contributor.author Kladas, AG en
dc.date.accessioned 2014-03-01T02:53:54Z
dc.date.available 2014-03-01T02:53:54Z
dc.date.issued 2012 en
dc.identifier.issn 00189464 en
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/36485
dc.subject Magnetic cores en
dc.subject magnetic field measurement en
dc.subject magnetic losses en
dc.subject power transformers en
dc.subject.other Excitation currents en
dc.subject.other Experimental evidence en
dc.subject.other Flux densities en
dc.subject.other Flux distributions en
dc.subject.other Grain oriented electrical steel en
dc.subject.other Grain-oriented steel en
dc.subject.other Harmonics content en
dc.subject.other High magnetization en
dc.subject.other High permeability en
dc.subject.other Low costs en
dc.subject.other Low permeability en
dc.subject.other Nonuniformity en
dc.subject.other Three-phase transformers en
dc.subject.other Transformer core en
dc.subject.other Wave forms en
dc.subject.other Wound core en
dc.subject.other Magnetic cores en
dc.subject.other Magnetic field measurement en
dc.subject.other Magnetic leakage en
dc.subject.other Power transformers en
dc.subject.other Silicon steel en
dc.subject.other Silicon en
dc.title Mixed Si-Fe wound cores five legged transformer: Losses and flux distribution analysis en
heal.type conferenceItem en
heal.identifier.primary 10.1109/TMAG.2011.2172929 en
heal.identifier.secondary http://dx.doi.org/10.1109/TMAG.2011.2172929 en
heal.identifier.secondary 6172335 en
heal.publicationDate 2012 en
heal.abstract This paper proposes a three-phase five legged wound transformer core constructed of two high permeability Si-Fe wound cores and two conventional Si-Fe wound cores. The two large internal wound cores are manufactured of high permeability, grain-oriented electrical steel. The two small outer wound cores are manufactured of conventional, grain-oriented electrical steel. The specific arrangement is based on experimental evidence concerning the peak flux density non-uniformity of the typical three-phase five legged wound transformer core, constructed of the high magnetization grain-oriented steel. Since the peak flux density of the two outer cores is lower than the two internal cores, low cost, low permeability, conventional grain-oriented electrical steel can be used for the outer cores. Losses, excitation currents, flux waveforms, and their harmonics contents are presented in this paper. A comparison of the mixed three-phase transformer core and the typical one is also carried out. © 2006 IEEE. en
heal.journalName IEEE Transactions on Magnetics en
dc.identifier.doi 10.1109/TMAG.2011.2172929 en
dc.identifier.volume 48 en
dc.identifier.issue 4 en
dc.identifier.spage 1609 en
dc.identifier.epage 1612 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής