Bearing capacity and strengthening of a multi-storey reinforced concrete hotel

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Μπελιβάνης, Αλέξανδρος el
dc.contributor.author Belivanis, Alexandros en
dc.date.accessioned 2016-09-30T10:27:16Z
dc.date.available 2016-09-30T10:27:16Z
dc.date.issued 2016-09-30
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/43710
dc.identifier.uri http://dx.doi.org/10.26240/heal.ntua.5620
dc.description Εθνικό Μετσόβιο Πολυτεχνείο--Μεταπτυχιακή Εργασία. Διεπιστημονικό-Διατμηματικό Πρόγραμμα Μεταπτυχιακών Σπουδών (Δ.Π.Μ.Σ.) "Analysis and Design of Earthquake Resistant Structures" el
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/gr/ *
dc.subject Bearing capacity en
dc.subject Strengthening en
dc.subject Concrete en
dc.subject Structure en
dc.subject Φέρουσα ικανότητα el
dc.subject Ενίσχυση el
dc.subject Σκυρόδεμα el
dc.subject Κατασκευή el
dc.title Bearing capacity and strengthening of a multi-storey reinforced concrete hotel en
heal.type masterThesis
heal.classification Structural engineering en
heal.classificationURI http://skos.um.es/unesco6/330532
heal.language en
heal.access free
heal.recordProvider ntua el
heal.publicationDate 2016-07
heal.abstract This project’s aim is not only to study the bearing capacity of a multi-storey reinforced concrete hotel, but also to study its strengthening. The hotel constructed in 1967 in Greece in seismic zone 2 area (Z2, aGR/g=0.24) under the provision of the national codes of Members of Reinforced Concrete (1954) and of the Design Code for Earthquake Resistant structures (1959). It is a 5-storey reinforced concrete building with underground floor, ground floor (two levels), mezzanine floor, approachable and non approachable roof. Its overall high is 27.53m, including the non approachable roof, while the typical high of floors is 3.2m. SAP2000 is used for the analyses of the building. Modal response spectrum analysis, nonlinear static (pushover) analyses and nonlinear dynamic time-history analyses are performed. Three pairs of acceleration time histories are used. They are the earthquakes events of Corinth (1981, magnitude: 6.6), Kalamata (1986, magnitude 6.2) and L’Aquila-Italy (2009 magnitude: 6.3). The acceleration time-histories are obtained by the PEER Ground Motion Data Base-Beta version. The acceleration time-histories are scaled. The assessment of the bearing capacity shows that the structure requires rehabilitation. The rehabilitation aim is to reach the life safety performance level. Nonlinear static (pushover) analyses and nonlinear dynamic time-history analyses are performed to the retrofitted structure, showing that the target-performance level is succeeded, when seismic action corresponding to seismic return period of 475 years, or the scaled L’Aquila, Corinth, Kalamata acceleration time-histories are imposed to the structure. en
heal.advisorName Κουμούσης, Βλάσιος el
heal.committeeMemberName Λαγαρός, Νικόλαος el
heal.committeeMemberName Νεραντζάκη, Μαρία el
heal.academicPublisher Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Πολιτικών Μηχανικών el
heal.academicPublisherID ntua
heal.numberOfPages 332 σ. el
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα