HEAL DSpace

Διαχείριση της ζήτησης για την αντιμετώπιση των επιπτώσεων των τεχνολογιών χαμηλών εκπομπών άνθρακα στα δίκτυα διανομής χαμηλής τάσης

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Αβραμίδης, Ιάσων el
dc.contributor.author Avramidis, Iason en
dc.date.accessioned 2017-07-21T10:03:52Z
dc.date.available 2017-07-21T10:03:52Z
dc.date.issued 2017-07-21
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/45309
dc.identifier.uri http://dx.doi.org/10.26240/heal.ntua.14563
dc.rights Default License
dc.subject Τεχνολογίες χαμηλών εκπομπών άνθρακα el
dc.subject Επίπεδο διείσδυσης el
dc.subject Δυναμικός έλεγχος κατανάλωσης el
dc.subject Πιθανοτική ροή ισχύος el
dc.subject Μέθοδος Monte Carlo el
dc.subject LCT and penetration level en
dc.subject Dynamic demand management en
dc.subject Probabilistic power flow en
dc.subject Monte Carlo method en
dc.title Διαχείριση της ζήτησης για την αντιμετώπιση των επιπτώσεων των τεχνολογιών χαμηλών εκπομπών άνθρακα στα δίκτυα διανομής χαμηλής τάσης el
heal.type bachelorThesis
heal.classification Ανάλυση συστημάτων ηλεκτρικής ενέργειας el
heal.classificationURI http://data.seab.gr/concepts/707c57739e834d52063aeb539e96b4e273ff9a06
heal.language el
heal.access free
heal.recordProvider ntua el
heal.publicationDate 2017-06-09
heal.abstract Σκοπός της διπλωματικής εργασίας είναι η μελέτη των επιπτώσεων στα δίκτυα διανομής χαμηλής τάσης των τεχνολογιών χαμηλών εκπομπών άνθρακα (Low Carbon Technologies-LCT), όπως των ανανεώσιμων πηγών ενέργειας ή των συσκευών κατανάλωσης ηλεκτρικής ενέργειας, των οποίων η λειτουργία δεν συνοδεύεται από υψηλά επίπεδα εκπομπών άνθρακα. Συγκεκριμένα, η μελέτη εστιάζεται κυρίως σε θέματα αξιοπιστίας εξυπηρέτησης καταναλωτών (τήρησης ορίων μέτρου τάσης) και θερμικής αντοχής των επιμέρους στοιχείων του δικτύου. Τυχόν προβλήματα που προκύπτουν αντιμετωπίζονται χωρίς άμεση επίδραση του χειριστή ούτε μέσω μοντέρνων συσκευών (ηλεκτρονικά ισχύος), αλλά με εσωτερικές μεθόδους, όπως ο δυναμικός έλεγχος κατανάλωσης, σε μια προσπάθεια μετάβασης από το "έξυπνο" δίκτυο, σε ένα οικονομικότερο και εν γένει αποδοτικότερο δίκτυο το οποίο "προλαβαίνει" πιθανά προβλήματα. Δηλαδή, δεν είναι επιθυμητή η επί τόπου αντιμετώπιση των προβλημάτων αλλά η καθολική πρόληψη αυτών. el
heal.abstract The scope of this Diploma Thesis is to study the impact on low voltage distribution networks of Low-Carbon Technologies (LCT), i.e., renewable energy sources or electrical energy consumption appliances, whose operation is not accompanied by high levels of carbon emissions. Specifically, the study focuses mainly on matters of service reliability (compliance with voltage limits) and thermal endurance of the various grid parts. Any problems that arise are addressed without direct influence from the operator or via modern devices (power electronics), but with internal processes such as dynamic demand management, in an attempt to move from the "smart grid", to the grid that "anticipates" potential problems making it cheaper and generally more efficient. In short, what is desired is not on-the-spot management of arising problems, but their total prevention altogether. In this work, multiple simulation algorithms were developed in a combined MATLAB and OpenDSS programming environment to achieve the objectives of the Thesis. It should be stressed that what matters is the study and proper operation of existing grids rather than the optimal development and optimal installation and operation of LCT. Relationships between LCT penetration level and grid operation are explored, focusing in particular on the voltage, current and power, the main aspects compiling the problem. For the grid operation study, the method of probabilistic power flow is employed, which is solved by the Monte Carlo method. For any problematic situations that arise, additional measures are implemented, specifically dynamic demand management, which is achieved through several approaches. The purpose of these additional measures is to normalize energy consumption in order to reduce LCT impact as much as possible. Having redefined the new consumption, grid operation is once again defined through the probabilistic power flow method. For the evaluation of the methods of the Thesis, a wide range of LCT and consumer loads was used, all of which were accompanied by a certain uncertainty and randomness, in order the conditions to be as realistic as possible in terms of weather conditions and human factor. The LCT used include both electricity production and consumption so as to cover the full range of the study. The LCT selection criteria were ease of installation for the consumer, pros and cons of each technology, and studies on the possible future state of distribution networks. The studied networks are plentiful in both buses and kilometers of distribution lines, hence as size criterion only the number of loads was used. Four grid sizes were used: small (23 loads), medium (55 loads), large (112 loads), and quite big (175 loads) from an existing database of actual UK distribution network topologies. The LCT penetration levels range from 0% to 100%. The final results are presented and compared and useful conclusions are drawn. en
heal.advisorName Γεωργιλάκης, Παύλος el
heal.committeeMemberName Βουρνάς, Κωνσταντίνος el
heal.committeeMemberName Κορρές, Γεώργιος el
heal.academicPublisher Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών. Τομέας Ηλεκτρικής Ισχύος el
heal.academicPublisherID ntua
heal.numberOfPages 120 σ. el
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής