dc.contributor.author |
Τζάνη, Δήμητρα
|
el |
dc.contributor.author |
Tzani, Dimitra
|
en |
dc.date.accessioned |
2019-04-01T09:38:07Z |
|
dc.date.available |
2019-04-01T09:38:07Z |
|
dc.date.issued |
2019-04-01 |
|
dc.identifier.uri |
https://dspace.lib.ntua.gr/xmlui/handle/123456789/48558 |
|
dc.identifier.uri |
http://dx.doi.org/10.26240/heal.ntua.15889 |
|
dc.rights |
Default License |
|
dc.subject |
Υλικά αλλαγής φάσης |
el |
dc.subject |
Παθητικά ηλιακά συστήματα |
el |
dc.subject |
Θέρμανση |
el |
dc.subject |
Ψύξη |
el |
dc.subject |
Λανθάνουσα θερμότητα |
el |
dc.subject |
PCM |
en |
dc.subject |
Energy Plus |
el |
dc.subject |
Thermal performance |
el |
dc.subject |
Building |
el |
dc.subject |
Latent heat |
el |
dc.title |
Διερεύνηση της ενεργειακής απόδοσης στρώματος υλικού αλλαγής φάσης στο κέλυφος κτιρίου με χρήση του λογισμικού Energy Plus |
el |
dc.title |
Study of the thermal performance of a building with phase change material layer in the building shell using the Energy Plus software |
en |
heal.type |
bachelorThesis |
|
heal.classification |
Ηλιακή ενέργεια |
el |
heal.classification |
Θέρμανση |
el |
heal.classification |
Ψύξη |
el |
heal.classificationURI |
http://data.seab.gr/concepts/e7b90a6ad212d31a3951b11cab47fa22956e9b7a |
|
heal.classificationURI |
http://data.seab.gr/concepts/e28f7158e6b5a7ea8a761c16a60839b122429a60 |
|
heal.classificationURI |
http://data.seab.gr/concepts/110ac37eff2b603f1775724ef374f54b7ba1ddc0 |
|
heal.access |
free |
|
heal.recordProvider |
ntua |
el |
heal.publicationDate |
2018-09-24 |
|
heal.abstract |
Αντικείμενο της παρούσας διπλωματικής εργασίας αποτελεί η μελέτη της θερμικής συμπεριφοράς ενός απλοποιημένου κτιρίου, το οποίο περιέχει στο κέλυφός του υλικό αλλαγής φάσης. Συγκεκριμένα, διερευνάται η επίδραση των υλικών αλλαγής φάσης στη διακύμανση της ωριαίας θερμοκρασίας στο εσωτερικό του κτιρίου, καθώς και στη διακύμανση της ενέργειας που καταναλώνεται από το σύστημα θέρμανσης-ψύξης. Χρησιμοποιήθηκαν και μελετήθηκαν υλικά αλλαγής φάσης, με διαφορετικά σημεία τήξης τοποθετημένα σε διαφορετικά σημεία του κελύφους του κτιρίου (τοίχους και οροφή), κατά τη θερινή και κατά τη χειμερινή περίοδο. Ο σχεδιασμός του απλοποιημένου κτιρίου έγινε με χρήση του λογισμικού Sketch Up Make με το Plug-in του Open Studio και για τη προσομοίωση του χρησιμοποιήθηκε το λογισμικό Energy Plus. |
el |
heal.abstract |
This diploma thesis investigates the thermal performance of a simplified building, which contains phase change material in the building shell. In particular, the effect of phase change materials on the fluctuation of the hourly temperature inside the building, as well as the variance of the energy consumed by the heating-cooling system are studied. Phase change materials with different melting points were used and studied at different points of the building shell (walls and roof) during the summer and winter season. The design of the simplified building was created using the Sketch Up Make software with the Open Studio Plug-in, and the Energy Plus software was used to simulate it. The first chapter describes the prevailing energy situation in modern times on a global and Greek scale, with an emphasis on the building sector. The second chapter analyzes the concept of bioclimatic design and thermal comfort and explains the ways of using solar energy by active and passive heating systems. Then the third chapter contains theoretical facts about the phenomenon of phase change and explanations about the concept of thermal energy storage. In the fourth chapter we are informed about the phase change materials, the properties they need to have and the categories they belong to, and in the fifth chapter the ways of incorporating the phase change materials into the building materials are analyzed. The sixth chapter presents the problems of the phase change materials during their use and the ways of their treatment and the seventh chapter presents the main building applications in which phase change materials have been used. In the eighth chapter there is a detailed description of the building design in Sketch Up and of the stages of completing the Energy Plus parameters that create the building’s profile. In the ninth chapter, we extracted and studied the results of the simulation. Specifically, a peak temperature drop of 1,632 C was observed during the summer period using phase change material with a melting point of 27°C and a maximum increase of 2,498 C was detected during the winter period using a phase change material of 18°C. Also it was shown that phase change materials were more efficient when placed on ceiling and walls, with the phase change material of 29°C positioned in this way, achieving maximum savings of the energy, consumed by the heating-cooling system, with a percentage of 13,32%. In the tenth and final chapter, the conclusions drawn from the study, as well as the possible areas of future research, are highlighted. |
en |
heal.advisorName |
Τζιβανίδης, Χρήστος |
el |
heal.committeeMemberName |
Τζιβανίδης, Χρήστος |
el |
heal.committeeMemberName |
Αντωνόπουλος, Κίμων |
el |
heal.committeeMemberName |
Κορωνάκη, Ειρήνη |
el |
heal.academicPublisher |
Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Μηχανολόγων Μηχανικών. Τομέας Θερμότητας |
el |
heal.academicPublisherID |
ntua |
|
heal.numberOfPages |
165 σ. |
|
heal.fullTextAvailability |
true |
|