HEAL DSpace

Επίδραση των υλικών αλλαγής φάσης στην ενεργειακή απόδοση των παθητικών ηλιακών συστημάτων

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Σιόντη, Βασιλική el
dc.contributor.author Sionti, Vasiliki en
dc.date.accessioned 2019-04-01T09:56:15Z
dc.date.available 2019-04-01T09:56:15Z
dc.date.issued 2019-04-01
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/48559
dc.identifier.uri http://dx.doi.org/10.26240/heal.ntua.15885
dc.rights Default License
dc.subject Υλικά αλλαγής φάσης el
dc.subject Παθητικά ηλιακά συστήματα el
dc.subject Θερμική συμπεριφορά κτιρίων el
dc.subject Τοίχος Trombe el
dc.subject Παθητική θέρμανση el
dc.subject Trombe wall en
dc.subject Phase change materials en
dc.subject PCM en
dc.subject EnergyPlus el
dc.subject Sketch Up el
dc.subject Ενεργειακή μελέτη el
dc.subject Passive solar systems en
dc.subject Latent heat en
dc.subject Λανθάνουσα θερμότητα el
dc.title Επίδραση των υλικών αλλαγής φάσης στην ενεργειακή απόδοση των παθητικών ηλιακών συστημάτων el
dc.title The effect of phase change materials on the energy efficiency of passive solar systems en
heal.type bachelorThesis
heal.classification Ηλιακή ενέργεια el
heal.classification Θέρμανση el
heal.classification Ψύξη el
heal.classification Κλιματισμός el
heal.classification Μεταφορά θερμότητας el
heal.classificationURI http://data.seab.gr/concepts/e7b90a6ad212d31a3951b11cab47fa22956e9b7a
heal.classificationURI http://data.seab.gr/concepts/e28f7158e6b5a7ea8a761c16a60839b122429a60
heal.classificationURI http://data.seab.gr/concepts/110ac37eff2b603f1775724ef374f54b7ba1ddc0
heal.language el
heal.access free
heal.recordProvider ntua el
heal.publicationDate 2018-09-24
heal.abstract Αντικείμενο της παρούσας διπλωματικής εργασίας αποτελεί η επίδραση των υλικών αλλαγής φάσης στο παθητικό ηλιακό σύστημα εμμέσου κέρδους, τον τοίχο Trombe Michel. Συγκεκριμένα, πραγματοποιείται η ενεργειακή μελέτη ενός απλοποιημένου μοντέλου κατοικίας που περιλαμβάνει διάταξη τοίχου Trombe με προσθήκη υλικών αλλαγής φάσης. Ο τοίχος Trombe απαιτεί μεγάλη θερμική μάζα κάτι το οποίο συνεπάγεται βαριές και ογκώδεις κατασκευές. Η ιδέα χρήσης υλικών αλλαγής φάσης, στο συγκεκριμένο σύστημα, προήλθε από την ιδιότητα τους να αποθηκεύουν μεγάλες ποσότητες θερμικής ενέργειας απαιτώντας πολύ μικρότερο χώρο σε σχέση με τα συμβατικά δομικά υλικά. Για την διεξαγωγή της παρούσας μελέτης εξετάζεται η επίδραση που έχουν διαφορετικές εκδοχές του τοίχου Trombe σε μια απλοποιημένη κατοικία στην τοποθεσία της Αθήνας. Οι διαφορετικές εκδοχές του τοίχου Trombe αφορούν την διαφορετική κατασκευή του τοίχου θερμικής μάζας η οποία περιλαμβάνει διαφορετικούς συνδυασμούς δομικών υλικών και υλικών αλλαγής φάσης. Η μελέτη πραγματοποιείται μέσω ενεργειακών προσομοιώσεων που διεξάγονται με χρήση του λογισμικού EnergyPlus. el
heal.abstract The subject of this diploma thesis is the effect of phase change materials on the indirect gain passive solar system, the Trombe-Michel wall. In particular, the energy study of a simplified building model including a Trombe wall with the addition of phase change materials is carried out. The Trombe wall requires a large thermal mass which involves heavy and bulky structures. The idea of using phase change materials in this system came from their ability to store large amounts of thermal energy requiring much less space than conventional building materials. For the purpose of the present study, the effect of different versions of the Trombe wall on a simplified building in the location of Athens is investigated. The different versions of the Trombe wall refer to the different construction of the thermal mass wall, which includes different combinations of building materials and phase change materials. The study is carried out through energy simulations performed with the EnergyPlus software. The first chapter analyzes the energy situation, trends and forecasts as well as energy consumption in buildings. The second chapter develops the principles of bioclimatic design and the ways in which it is applied. Also, it describes the arrangements and mode of operation of passive solar systems, systems and techniques of natural cooling and natural lighting systems. The third chapter includes how the Trombe Michel wall operates and its basic features. The fourth chapter analyzes the thermal energy storage mechanism using phase change materials, the categories and problems that arise during their use. The fifth chapter deals with the ways of storing thermal energy in buildings using phase change materials, the devices through which they are achieved, and how they are incorporated into building materials. The sixth chapter presents the building design that was created through the Sketch Up software with the Open Studio plug-in and describes in detail the structure of the Energyplus simulation files. The seventh chapter presents the results and conclusions that have emerged as well as some proposals for future studies. In particular, it has been found that in a 45 cm thick thermal mass wall replacing 20 of the 40 cm concrete with 1 cm of BioPCM Q29, the total thickness is reduced by 42.22% and the thermal behavior of the building is improved throughout the year. It increases indoor temperatures in winter, reduces the summer temperatures and improves the thermal storage capacity of the wall. It was also found that replacing 40 cm of concrete with 1 cm of BioPCM Q29 and 4 cm of plasterboard also improved thermal storage capacity of the thermal mass wall. There is a reduction in the total thickness by 77.78%, the passive cooling of the building is improved, but the temperatures during the winter are generally lower. Finally, it has been shown that the installation of a shading device in the Trombe wall improves the operation of the device throughout the year. en
heal.advisorName Τζιβανίδης, Χρήστος el
heal.committeeMemberName Αντωνόπουλος, Κίμων el
heal.committeeMemberName Τζιβανίδης, Χρήστος el
heal.committeeMemberName Ρογδάκης, Εμμανουήλ el
heal.academicPublisher Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Μηχανολόγων Μηχανικών. Τομέας Θερμότητας. Εργαστήριο Ψύξης και Κλιματισμού el
heal.academicPublisherID ntua
heal.numberOfPages 171 σ.
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής