Μεθοδολογία αξιολόγησης έργων οδοφωτισμού με δυνατότητα επιλογής των ποιοτικών και ποσοτικών δεικτών ποιότητας του έργου

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Τάντουλος, Γεράσιμος-Φίλιππος el
dc.contributor.author Tantoulos, Gerasimos-Filippos en
dc.date.accessioned 2019-06-21T08:12:41Z
dc.date.available 2019-06-21T08:12:41Z
dc.date.issued 2019-06-21
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/48873
dc.identifier.uri http://dx.doi.org/10.26240/heal.ntua.15509
dc.rights Default License
dc.subject Προσαρμοστικός φωτισμός el
dc.subject Φωτορύπανση el
dc.subject Θάμβωση δυσφορίας el
dc.subject Θάμβωση ανικανότητας el
dc.subject Ομοιόμορφος φωτισμός el
dc.subject Μέθοδος ΑHP el
dc.subject Μέθοδος PROMETHEE el
dc.subject Adaptive lighting en
dc.subject Light pollution en
dc.subject Discomfort glare en
dc.subject Disability glare en
dc.subject Uniformity en
dc.subject AHP method en
dc.subject PROMETHEE method en
dc.title Μεθοδολογία αξιολόγησης έργων οδοφωτισμού με δυνατότητα επιλογής των ποιοτικών και ποσοτικών δεικτών ποιότητας του έργου el
heal.type bachelorThesis
heal.classification Οδοφωτισμός el
heal.language el
heal.access free
heal.recordProvider ntua el
heal.publicationDate 2019-03-07
heal.abstract Η παρούσα διπλωματική εργασία μελετάει μεθόδους αξιολόγησης έργων οδοφωτισμού με δυνατότητα επιλογής των ποιοτικών και ποσοτικών δεικτών ποιότητας του έργου. Για το σκοπό αυτό ένα μεγάλο της εργασίας αφιερώθηκε στον υπολογισμό και την αξιολόγηση εγκαταστάσεων οδοφωτισμού, οι οποίες χαρακτηρίζονταν από διαφορετικούς στόχους κάθε φορά. Πιο συγκεκριμένα υλοποιήθηκαν τα παρακάτω εναλλακτικά σενάρια : ένα σενάριο οικονομικότερης υλοποίησης (με την χρήση των δεικτών Dp,De), ένα σενάριο περιορισμού της φωτορύπανσης (με την χρήση του δείκτη UFR), ένα σενάριο μειωμένης θάμβωσης (με την χρήση του δείκτη ΤΙ) και τέλος ένα σενάριο μεγιστοποίησης της ομοιομορφίας της λαμπρότητας (με την χρήση του δείκτη Uo). Τα παραπάνω σενάρια υλοποιήθηκαν σε δυο ενδεικτικούς καννάβους και αξιολογήθηκαν με βάση τεχνικούς δείκτες όπως: ΦΑ,UF,Νp,Ninst. Επιπλέον, για κάθε σενάριο πραγματοποιήθηκε και τεχνοοικονομική μελέτη με στόχο να συγκριθούν οι παραπάνω εγκαταστάσεις οδοφωτισμού και για το κόστος εγκατάστασης και κατανάλωσής τους. Τέλος, με την χρήση των μεθόδων ΑΗΡ και PROMETHHE υπολογίσθηκε η κατάταξη των εναλλακτικών σεναρίων για δυο διαφορετικά πολυκριτηριακά προβλήματα, όπου το κάθε πρόβλημα είχε διαφορετική κατανομή στα βάρη των κριτηρίων. el
heal.abstract This diploma thesis focuses on the methodology of evaluation of street lighting projects with the possibility of selecting the qualitative and quantitative quality indicators of the project. To this end, a major work was devoted to the calculation and evaluation of street lighting installations, which were characterized by different objectives at a time. In the first chapter, an introduction to the visible spectrum, color temperature is made, while fundamental photometry is also analyzed. The second chapter is dedicated to LED luminaires, their optic system and to OLED technology. In the third chapter, the Technical Report CEN/TR 13201-1 which used for the street lighting installations is analyzed, along with an alternative method of calculating classes (Annex). In the fourth chapter the two methods of class selection are compared through three scenarios and the outcome is quite interesting. In the fifth chapter, it was considered appropriate to investigate and present how the European Standard for street lighting installations is applied in various European countries. European countries, through specific laws or directives in their national road lighting guide, have enriched the common European guidebook of Member States. The sixth chapter presents in theory alternative scenarios of street lighting installations of different objectives. Therefore, installations which allow significant reductions in energy consumption are presented, then the phenomenon of light pollution is explained and finally factors that contribute to the visual comfort of the user such as glare and uniformity of luminance are analyzed. Also, the purpose of the chapter is to explain why an installation with quality lighting objectives is important. In the seventh chapter alternative scenarios are calculated and evaluated through simulations (software programs such as Dialux and Oxytech are used). In particular, the following scenarios have been calculated: a scenario of economical implementation (based on Dp, De), a reduced light pollution scenario (based on UFR), a reduced glare scenario (based on TI), a maximal uniformity scenario (based on Uo). The above scenarios were implemented in two indicative girds and were evaluated by technical indicators such as: ΦΑ,UF,Νp,Ninst, while for each scenario, a feasibility study was carried out to assess the cost of their installation and consumption. The eighth chapter, presents the theory of multicriteria problem analysis, the AHP weighting and the PROMETHEE method. In the ninth chapter, the methods analyzed in the eighth chapter are used to select the most appropriate scenario from those calculated in chapter seven based on the preference of the decision-maker. Indeed, the classification of the alternative scenarios was calculated for two different problems where each problem had a different distribution over the criteria weights. Finally, chapter 10 sums up the observations and conclusions from the whole thesis and proposes topics that would be of interest in further research as they were born out of this diploma thesis. en
heal.advisorName Τοπαλής, Φραγκίσκος el
heal.committeeMemberName Γκόνος, Ιωάννης el
heal.committeeMemberName Γεωργιλάκης, Παύλος el
heal.academicPublisher Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών. Τομέας Ηλεκτρικής Ισχύος el
heal.academicPublisherID ntua
heal.numberOfPages 164 σ.
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής