dc.contributor.author | Σκαμάγκας, Κωνσταντίνος | |
dc.contributor.author | Skamagkas, Konstantinos | |
dc.date.accessioned | 2020-09-09T10:33:36Z | |
dc.date.available | 2020-09-09T10:33:36Z | |
dc.identifier.uri | https://dspace.lib.ntua.gr/xmlui/handle/123456789/51074 | |
dc.identifier.uri | http://dx.doi.org/10.26240/heal.ntua.18772 | |
dc.description | Εθνικό Μετσόβιο Πολυτεχνείο--Μεταπτυχιακή Εργασία. Διεπιστημονικό-Διατμηματικό Πρόγραμμα Μεταπτυχιακών Σπουδών (Δ.Π.Μ.Σ.) “Δομοστατικός Σχεδιασμός και Ανάλυση των Κατασκευών” | el |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/gr/ | * |
dc.subject | Αποτίμηση | el |
dc.subject | Αποτίμηση κατασκευής | el |
dc.subject | Οπλισμένο σκυρόδεμα | el |
dc.subject | Διατμητικά τοιχώματα | el |
dc.subject | Ανελαστική ανάλυση | el |
dc.subject | Assessment | en |
dc.subject | Responce spectrum | en |
dc.subject | Pushover analysis | en |
dc.subject | Shear walls | en |
dc.subject | Reinforced concrete | en |
dc.title | Αποτίμηση φέρουσας ικανότητας πολυώροφου κτιρίου από οπλισμένο σκυρόδεμα | el |
dc.title | Assessment of a multi-story RC bulding's bearing & seismic capacity constructed in the 1960's | en |
dc.contributor.department | Δομοστατικός Σχεδιασμός και Ανάλυση Κατασκευών | el |
heal.type | masterThesis | |
heal.classification | Στατική Ανάλυση | el |
heal.language | el | |
heal.access | free | |
heal.recordProvider | ntua | el |
heal.publicationDate | 2020-03-05 | |
heal.abstract | Αντικείμενο της παρούσας μεταπτυχιακής εργασίας, που εκπονήθηκε στο πλαίσιο του Μεταπτυχιακού Προγράμματος Σπουδών με τίτλο «Δομοστατικός Σχεδιασμός και Ανάλυση των Κατασκευών», είναι η αποτίμηση της φέρουσας ικανότητας ενός κτιρίου από οπλισμένο σκυρόδεμα της δεκαετίας του ́60. Πρόκειται για κτίριο με φέροντα οργανισμό από οπλισμένο σκυρόδεμα που διαθέτει ισόγειο και τρεις ορόφους, του οποίου η αρχική μελέτη εκπονήθηκε το 1961 με το τότε ισχύον πλαίσιο κανονισμών. Για την αποτίμηση της φέρουσας ικανότητας του φορέα χρησιμοποιήθηκε το πρόγραμμα SAP2000 v20.2.0. Σε πρώτο στάδιο, πραγματοποιήθηκε όσο το δυνατόν ακριβέστερη προσομοίωση του φέροντος οργανισμού του φορέα, ήτοι τα γεωμετρικά του στοιχεία, τα υλικά κατασκευής του (Ποιότητα σκυροδέματος – χάλυβας οπλισμού), καθώς και οι διατομές οπλισμού ανά διατομή με βάση τις διαθέσιμες κατόψεις ξυλοτύπων ανά οροφή του κτιρίου που αποτιμάται στη παρούσα. Εν συνεχεία, εφαρμόσθηκαν αναλύσεις σεισμικής αποτίμησης της υφιστάμενης κατασκευής όπως προσομοιώθηκε, ως εξής, αρχικά πραγματοποιήθηκε ελαστική ανάλυση και ακολούθως ανελαστική ανάλυση (pushover), των οποίων οι αρχές και οι κανόνες εφαρμογής περιγράφονται στις διατάξεις του ΚΑΝ.ΕΠΕ και του Ευρωκώδικα 8 (EN-8). Όσον αφορά την ελαστική ανάλυση, εφαρμόστηκε η Δυναμική Φασματική Μέθοδος με χρήση του φάσματος του Ευρωκώδικα 8 και παρουσιάζονται τα αποτελέσματα (π.χ. μέγιστα εντατικά μεγέθη) που προκύπτουν από τη χρήση της μεθόδου. Όσον αφορά, την ανελαστική ανάλυση εφαρμόστηκε η μη γραμμική στατική μέθοδος Pushover υπό την οποία η κατασκευή υποβάλλεται σε αυξανόμενες οριζόντιες φορτίσεις και στις δύο διευθύνσεις μέχρι την κατάρρευση του κτιρίου. Από τη μη γραμμική ανάλυση προκύπτουν οι καμπύλες αντίστασης της κατασκευής δηλαδή τα διαγράμματα τέμνουσας βάσης - μετακίνησης κόμβου ελέγχου της κατασκευής καθώς και τα διαγράμματα ADRS. Τονίζεται, ότι η αποτίμηση της σεισμικής τρωτότητας του κτιρίου με χρήση μη γραμμικών μεθόδων αντιπροσωπεύει τη σύγχρονη πλέον λογική σχεδιασμού, δηλαδή τον σχεδιασμό με στάθμες επιτελεστικότητας (Performance Based Design). Τέλος, προτείνονται κατευθύνσεις επεμβάσεων και ενίσχυσης της υφιστάμενης κατασκευής, επί των οποίων παρουσιάζονται και τα αποτελέσματα των ανωτέρω αναλύσεων προς σύγκριση του νέου και ενισχυμένου φορέα με τον υφιστάμενο -κατασκευασμένο προ 50ετίας- φορέα. | el |
heal.abstract | Greece is known as a Country with frequent seismic activity. There is a quite large number of buildings in Greece that were erected before the 80’s under the provisions of the existing National Codes for design of concrete structures (1954) and design of earthquake resistant structures (1959). These codes were replaced in 1984 by more modern approaches with stricter design laws under seismic loading. The aim of this master thesis is the safety assessment of an existing multistory building and examining different reinforcing scenarios of its concrete frame. The building under valuation consists of a four-stores RC building (ground floor and three stores above) with a concrete roof (concrete slab), and more specifically, the building under valuation is a building found in the Rizareios Ekklisiastiki Sxoli Complex situated in Halandri, Attica in Greece. The building was constructed between 1960 – 1962, under the provisions of the above – mentioned existing Greek codes. The aim of this master thesis is the assessment of the structure’s seismic capacity and for that purpose, Linear and non-linear as well as analyses were used. These two different techniques were compared giving an insight to the pros and cons of each method. Analysis of the structure showed the need for additional reinforcements to the original concrete frame, in order to improve its seismic behavior. In the 1st chapter, a brief description of the subject of the master thesis is provided, as well as a brief abstract of the Rizareios Ekklisiastiki Sxoli background summary. In the 2nd chapter, there is an analytical description of the building and its simulation by using the SAP2000 (v20) software. The properties of the materials, the sections’ shape & characteristics, the applied loads and the design spectrum are defined. In the 3rd chapter, the linear methods were applied to the structure are analyzed and described. Modal analysis results, modal response spectrum and concrete design checks are presented. The modal analysis of the structure is presented downwards: In the 4th chapter, the fundamental concepts of the performance-based design are described in a full extend. In the 5th chapter, the nonlinear static analysis (pushover) approach is presented as well as its results. The performance point is computed for the lateral load combinations of the structure at hand. The result of most of the pushover analyses, were the failure of the 4 shear walls out of 5 checked. In chapter 6, the procedure of implementing strengthening techniques to the existing structure is presented. Two retrofitting scenarios are proposed and more specifically, at the 1st scenario the removal of the concrete roof in order to reduce some of the weight of the building is proposed, combined with the retrofitting of the shear walls that failed in the pushover analyses. At the 2nd scenario, the removal of the concrete roof is proposed also, as well as with the removal and the input of shear walls in both directions. At the 2nd scenario, the shear walls that were not removed and were failing at the pushover analyses of the 5th chapter, are being strengthened too. The retrofitted building’s behavior under seismic loading is compared to its original state. At both scenarios, the shear walls (retrofitted) were checked, and none was failing. | en |
heal.advisorName | Κουμούσης, Βλάσιος | |
heal.advisorName | Koumousis, Vlasios | |
heal.committeeMemberName | Κουμούσης, Βλάσιος | |
heal.committeeMemberName | Τριανταφύλλου, Σάββας | |
heal.committeeMemberName | Νερατζάκη, Μ. | |
heal.academicPublisher | Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Πολιτικών Μηχανικών | el |
heal.academicPublisherID | ntua | |
heal.numberOfPages | 139 | |
heal.fullTextAvailability | false |