dc.title | Ποιότητα αναπνεύσιμου αέρα εσωτερικών χώρων: Πειράματα και εφαρμογές | el |
dc.title | Breathing air quality of indoor spaces: Experiments and applications | en |
dc.contributor.department | Τομέας Φυσικής | el |
heal.type | bachelorThesis | |
heal.classification | Περιβάλλον | el |
heal.language | el | |
heal.access | free | |
heal.recordProvider | ntua | el |
heal.publicationDate | 2020-07-15 | |
heal.abstract | Στην παρούσα Διπλωματική Εργασία μελετάται η συγκέντρωση μάζας των αιωρούμενων σωματιδίων με διάμετρο μικρότερη από 2.5 μm (PM2.5) σε εσωτερικούς χώρους και η επίδρασή τους στην ανθρώπινη υγεία, με την χρήση του επίγειου οργάνου μέτρησης της εταιρίας TSI (DustTrak II Aerosol Monitor Model 8530). Τα συγκεκριμένα σωματίδια παρουσιάζουν ενδιαφέρον, καθώς η μικρή διάμετρος τους καθιστά εύκολη την είσοδο τους στον ανθρώπινο οργανισμό, κυρίως μέσω των πνευμόνων. Γίνεται σύγκριση με τα αντίστοιχα δεδομένα συγκέντρωσης μάζας εξωτερικού περιβάλλοντος τα οποία προέρχονται από μετρήσεις με τον Οπτικό Μετρητή Κατανομής Σωματιδίων (Optical Particle Counter, OPC model Grim 107 Dust Spectrometer) ο οποίος βρίσκεται εγκατεστημένος στο Εθνικό Κέντρο Έρευνας Φυσικών Επιστημών "ΔΗΜΟΚΡΙΤΟΣ" στην περιοχή Αγία Παρασκευή Αττικής και με το σύστημα lidar EOLE του Εργαστηρίου Ατμοσφαιρικής Τηλεπισκόπησης Laser στο Εθνικό Μετσόβιο Πολυτεχνείο. Συνεπώς, μελετάται η υποβάθμιση της ποιότητας του εσωτερικού ατμοσφαιρικού αέρα από δραστηριότητες εντός εσωτερικού χώρου. | el |
heal.abstract | The present Dissertation Thesis examines the mass concentration of airborne particles, with a diameter of less than 2.5 μm (PM2.5) in indoor spaces and their effect on human health. The instrument for ground measurements was the TSI (DustTrak II Aerosol Monitor Model 8530). These particles are interesting because their small diameter makes it easy for them to enter the human body, mainly through the lungs. A comparison is made with the corresponding mass concentration data for particles in outdoor spaces, obtained through measurements using the Optical Particle Counter (OPC model Grim 107 Dust Spectrometer) which is found at “Demokritos” National Research Center for Scientific Research in the area of Attica and the lidar EOLE system of the Laser Atmospheric Surveying Laboratory at the National Technical University of Athens. Therefore, the object is the study of the deterioration of the quality of indoor atmospheric air as a consequence of household activities. | en |
heal.abstract | Cette Thèse de Diplôme examine la concentration de masse de particules en suspension dans l'air, d'un diamètre inférieur de 2,5μm (PM2.5) dans les espaces intérieurs et leur effet sur la santé humaine. L'instrument utilisé pour les mesures au niveau du sol était le TSI (DustTrak II Aerosol Monitor Model 8530). Ces particules sont intéressantes car leur petit diamètre leur permet de pénétrer facilement dans le corps humain, principalement par biais des poumons. Une comparaison a été réalisée avec les données de concentration de masse; correspondantes aux particules dans les espaces extérieurs, obtenues par des mesures en utilisant le compteur de particules optiques (modèle OPC Grim 107 Dust Spectrometer) qui est situé au Centre National de Recherche en Sciences Naturelles «Democretus»; dans la région de l'Attique et le système lidar EOLE du Laser Atmospheric Surveying Laboratory de l'Université Technologique Nationale d'Athènes. Par conséquent, l'objet de cette thèse est d'étudier la détérioration de la qualité de l'air atmosphérique dans les espaces intérieurs, comme conséquence des activités domestiques. | fr |
heal.advisorName | Παπαγιάννης, Αλέξανδρος | |
heal.committeeMemberName | Κόκκαλης, Παναγιώτης | |
heal.committeeMemberName | Ρεμουντάκη, Εμμανουέλλα | |
heal.academicPublisher | Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Εφαρμοσμένων Μαθηματικών και Φυσικών Επιστημών. Τομέας Φυσικής | el |
heal.academicPublisherID | ntua | |
heal.numberOfPages | 166 σ. | el |
heal.fullTextAvailability | false |