Στην παρούσα διπλωματική εργασία μελετήθηκε η επιφανειακή δομή των δύο stents της εταιρίας
ev3 μέσω ηλεκτρονικής μικροσκοπίας σάρωσης και μετρήθηκε η μηχανική αντοχή του ενός
δοκιμίου σε πείραμα μονοαξονικού εφελκυσμού.
Στο πρώτο κεφάλαιο γίνεται μια εισαγωγή στο πρόβλημα της αθηροσκλήρωσης και περιγράφεται ο
σκοπός της επεμβατικής μεθόδου της τοποθέτησης stent.
Στο δεύτερο κεφάλαιο συνοψίζονται οι βασικοί τύποι stent όπου η κατάταξη γίνεται βάσει υλικού,
γεωμετρίας καθώς και δευτερευόντων χαρακτηριστικών.
Στο τρίτο κεφάλαιο, παρουσιάζονται οι απεικονίσεις των δύο stents κατά την ηλεκτρονική
μικροσκοπία σάρωσης και περιγράφεται η διαδικασία που ακολουθήθηκε προκειμένου να μετρηθεί
η αντοχή του δοκιμίου στο πείραμα του μονοαξονικού εφελκυσμού. Συγκεκριμένα, μελετήσαμε
την επιφανειακή υφή καθώς και το υλικό κατασκευής των δύο stents με την βοήθεια ηλεκτρονικού
μικροσκοπίου σάρωσης προκειμένου να βγάλουμε χρήσιμα συμπεράσματα για τη δομή καθώς και
την σύστασή τους. Οι συγκεκριμένες απεικονίσεις διενεργήθηκαν στο Ινστιτούτο Επιστήμης
Υλικών του Ε.Κ.Ε.Φ.Ε. “Δημόκριτος” και αποτελούν ένα από τα βασικά τμήματα αυτής της
εργασίας, αφού μας προσέφεραν σημαντικά στοιχεία για την επιφανειακή συνοχή των stents που
είχαμε στη διάθεση μας. Το πείραμα μονοαξονικού εφελκυσμού έγινε στο εργαστήριο Αντοχής
Υλικών του ΕΜΠ και σκοπό είχε την μελέτη της εφελκυστικής συμπεριφοράς του stent Visi-Pro.
Επιμηκύνοντας το stent με έναν συγκεκριμένο ρυθμό, καταγράφαμε την δύναμη που ασκούνταν σε
αυτό, κάτι που θα μας βοηθήσει στην ανάλυση της μηχανικής αντοχής του δοκιμίου μας.
Στο τέταρτο κεφάλαιο συνοψίζονται τα βασικά συμπεράσματα που προέκυψαν από την ανάλυση
των πειραματικών δεδομένων. Αυτά αφορούν τα πιο σημαντικά στοιχεία τα οποία παρατηρήθηκαν
κατά τις απεικονίσεις με το ηλεκτρονικό μικροσκόπιο καθώς και σχόλια για την συμπεριφορά του
stent κατά την επιμήκυνση του.
1 |
el |
dc.description.abstract |
In this thesis, we investigated the surface integrity of two stents of the company ev3 via scanning
electron microscopy, and measured the mechanical strength of one of the specimens in uniaxial
tensile testing.
The first chapter contains an introduction to the problem of atherosclerosis and describes the
purpose of the method of interventional stent placement.
The second chapter summarises the main types of stents available, in which classifications are made
according to stent material, geometry and secondary features.
The third chapter, in which the experimental results are presented, illustrates the high resolution
pictures that were obtained via scanning electron microscopy and describes the experimental setup
for the uniaxial tensile test. Specifically, we studied the surface integrity and the material properties
of the two stents through the use of a scanning electron microscope, in order to extract valuable
conclusions about their structure and their chemical composition. The aforementioned depictions
took place at the Materials Science Institute at N.C.S.R. 'Demokritos', and constitute an important
part of this thesis since they provided us with valuble information about the surface integrity of the
two specimens. The uniaxial tensile test took place in the Materials Strength laboratory at NTUA
and was conducted in order to facilitate the study of the tensile behaviour of the Visi-Pro stent. We
imposed an elongation of a specified rate on the stent and recorded the force that was exercised
upon it, a test that is very helpful towards our goal of evaluating the tensile strength of our
specimen.
The fourth chapter summarises the main conclusions drawn from the analysis of the experimental
data. These conclusions include the most important features that were observed during the
depictions obtained with the electron microscope, as well as comments regarding the tensile
behaviour of our stent, during the tensile strength testing.
2 |
en |
dc.description.statementofresponsibility |
Φάνης Α. Αντωνίου |
el |
dc.language.iso |
el |
en |
dc.rights |
ETDFree-policy.xml |
en |
dc.subject |
Στεντ |
el |
dc.subject |
Στένωση |
el |
dc.subject |
Μηχανική αντοχή |
el |
dc.subject |
Καρδιά |
el |
dc.subject |
Στεφανιαίο |
el |
dc.subject |
Coronary |
en |
dc.subject |
Stent |
en |
dc.subject |
SEM |
en |
dc.subject |
Load test |
en |
dc.subject |
Heart |
en |
dc.title |
Μελέτη των μηχανικών ιδιοτήτων των stents που χρησιμοποιούνται |
el |
dc.title.alternative |
Research in mechanical properties of medical stents |
en |
dc.type |
bachelorThesis |
el (en) |
dc.date.accepted |
2013-03-11 |
- |
dc.date.modified |
2013-07-19 |
- |
dc.contributor.advisorcommitteemember |
Μακροπούλου, Μυρσίνη |
el |
dc.contributor.advisorcommitteemember |
Κουρκούλης, Σταύρος |
el |
dc.contributor.committeemember |
Βλαστού, Ρόζα |
el |
dc.contributor.committeemember |
Μακροπούλου, Μυρσίνη |
el |
dc.contributor.committeemember |
Κουρκούλης, Σταύρος |
el |
dc.contributor.department |
Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Ηλεκτρολόγων Μηχανικών & Μηχανικών Η/Υ. Τομέας Φυσικης. |
el |
dc.date.recordmanipulation.recordcreated |
2014-02-06 |
- |
dc.date.recordmanipulation.recordmodified |
2014-02-06 |
- |