HEAL DSpace

Investigation of the seismic behavior of a newly constructed 7-story reinforced concrete building with a roof water tank

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Μουρλάς, Δημήτριος el
dc.contributor.author Mourlas, Dimitrios en
dc.date.accessioned 2023-11-16T12:13:39Z
dc.date.available 2023-11-16T12:13:39Z
dc.identifier.uri https://dspace.lib.ntua.gr/xmlui/handle/123456789/58297
dc.identifier.uri http://dx.doi.org/10.26240/heal.ntua.25993
dc.description Εθνικό Μετσόβιο Πολυτεχνείο--Μεταπτυχιακή Εργασία. Διεπιστημονικό-Διατμηματικό Πρόγραμμα Μεταπτυχιακών Σπουδών (Δ.Π.Μ.Σ.) “Δομοστατικός Σχεδιασμός και Ανάλυση των Κατασκευών” el
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/gr/ *
dc.subject Αποτίμηση κτιρίου el
dc.subject Διερεύνηση οικονομοτεχνικών απωλειών el
dc.subject Ανελαστική στατική ανάλυση el
dc.subject Προσεισμικός έλεγχος κτιρίου el
dc.subject Δεξαμενή νερού el
dc.subject Pushover analysis en
dc.subject Fragility curves en
dc.subject Roof water tank en
dc.subject Seismic loss assessment en
dc.subject Pact - FEMA P-58 en
dc.title Investigation of the seismic behavior of a newly constructed 7-story reinforced concrete building with a roof water tank en
heal.type masterThesis
heal.classification Structural Engineering en
heal.classification Reinforced Concrete en
heal.classification Seismic Assessment en
heal.language en
heal.access free
heal.recordProvider ntua el
heal.publicationDate 2023-07-05
heal.abstract A range of seismic assessment methods is employed to evaluate the seismic behavior of a newly constructed building and to estimate its seismic losses. For this scope, a 7-story building with a basement constructed in Kallithea, Greece in 2022 was studied. In addition, we studied the seismic behavior of an added roof water tank, this being the typical practice for several areas outside of Athens with low or inadequate water pressure. As such non-structural components are rarely designed by structural engineers, the aim is to investigate whether there will be damage due to the (typically amplified) roof top acceleration. The Rapid Visual Inspection method was used in order to classify the building in a priority category for further checking. For the second level rapid seismic assessment, the methods proposed by Dritsos S., Vougioukas E. and the new FEMA P-2018 guidelines were applied. In addition, nonlinear static analyses were performed based on the Greek code (KANEPE), Eurocode 8-Part 3, and ASCE/SEI 41-17. The Rapid Visual Inspection method revealed that the building belongs to the category with low priority for further checking, as expected of a newly designed structure. Regarding the results of the second level rapid seismic assessment methods and the nonlinear static analyses, considerable scatter is observed, with KANEPE being the most conservative approach. Furthermore, the analysis of the roof water tank showed that it failed at a peak ground acceleration PGA of 0.067g, or 40% of the design PGA, corresponding to an earthquake with a 35-year return period rather than the needed 475 years. Therefore, this water tank has a high probability of collapse during the lifetime of the building (50 years), potentially causing severe water damage to the roof, stairwell, and floor contents. Moreover, the fragility curves of the building were estimated using the SPO2FRAG software for both KANEPE and EC8, further showing the conservatism of KANEPE. Finally, the repair cost for various levels of building damage was estimated using the PACT software developed by FEMA P-58. The results showed that in all cases, the critical elements are generally the infills, the walls, and the roof water tank, although the average annual loss is low, reaching only 0.66% (KANEPE) to 0.16% (EC8) of the total building replacement cost. en
heal.advisorName Βαμβάτσικος, Δημήτριος el
heal.committeeMemberName Βαμβάτσικος, Δημήτριος el
heal.committeeMemberName Γαντές, Χάρης el
heal.committeeMemberName Θανόπουλος, Παύλος el
heal.academicPublisher Εθνικό Μετσόβιο Πολυτεχνείο. Σχολή Πολιτικών Μηχανικών el
heal.academicPublisherID ntua
heal.numberOfPages 256 σ. el
heal.fullTextAvailability false


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ελλάδα